This paper investigates the effects of over-voltage, under-voltage and unbalanced voltage on the performance of induction machines in terms of line currents, power factor and efficiency. A set of three motors of 50 hp, 100 hp and 300 hp respectively, has been tested thoroughly at five different voltage conditions: rated voltage, 10% over-voltage, 10% under-voltage, 1.25% unbalance, and 2.5% unbalance. At each one of these voltage conditions, a load run series was performed for every motor. The data obtained shows how the different motors behave similarly, in terms of line current and power factor and differently in terms of efficiency, when subject to the particular voltage conditions.
机译:本文从线电流,功率因数和效率的角度研究过电压,欠电压和不平衡电压对感应电机性能的影响。已分别在五个不同的电压条件下对一组三个分别为50 hp,100 hp和300 hp的电动机进行了全面测试:额定电压,10%过电压,10%欠电压,1.25%不平衡和2.5%不平衡。在这些电压条件中的每一个条件下,对每个电动机都执行负载运行序列。所获得的数据显示了在受到特定电压条件的情况下,不同的电动机在线路电流和功率因数方面如何表现相似,而在效率方面却表现不同。