首页> 外文会议>International Conference on Electrical machines and drives >The measured effects of under-voltage, over-voltage and unbalanced voltage on the efficiency and power factor of induction motors over wide ranges of load
【24h】

The measured effects of under-voltage, over-voltage and unbalanced voltage on the efficiency and power factor of induction motors over wide ranges of load

机译:欠电压,过电压和不平衡电压的测量效果对宽负载范围内的感应电动机效率和功率因数

获取原文
获取外文期刊封面目录资料

摘要

This paper investigates the effects of over-voltage, under-voltage and unbalanced voltage on the performance of induction machines in terms of line currents, power factor and efficiency. A set of three motors of 50 hp, 100 hp and 300 hprespectively, has been tested thoroughly at five different voltage conditions: rated voltage, 10% over-voltage, 10% under-voltage, 1.25% unbalance, and 2.5% unbalance. At each one of these voltage conditions, a load run series was performed for everymotor. The data obtained shows how the different motors behave similarly, in terms of line current and power factor and differently in terms of efficiency, when subject to the particular voltage conditions.
机译:本文研究了在线电流,功率因数和效率方面对电流机器性能的过电压,欠压和不平衡电压的影响。一套50 HP,100 HP和300 HPRespective的三种电动机已经在五种不同的电压条件下进行了彻底测试:额定电压,超过电压10%,欠压10%,不平衡1.25%,不平衡2.5%。在这些电压条件中的每一个中,对每个电流进行负载运行系列。所获得的数据示出了在当经受特定电压条件的情况下,在线电流和功率因数以及在效率方面的不同之处,不同的电动机的行为方式。