Abstract: To study the effects of RMP7, an bradykinin analog, on BBB permeability changes in brain tumor patients, Ga-68 EDTA PET was used for quantitative determination of tumor tissue permeability, two dynamic Ga-68 EDTA PET scans (with and without RMP7) were performed for each patient. Changes between the results of the two scans were used to assess the effect of the drug. MRI was also performed to provide the anatomical information. Patient movement during the dynamic PET studies were corrected by frame-to-frame PET image registration. Due to different orientation among PET and MRI images, all PET images were co-registered to the MRI images of the corresponding patient. All frames of a dynamic scan were summed before registering to the MRI images. The main features for registration were boundaries of skull and tumor. After registration, region of interest (ROI) was defined on MRI images and was copied to registered PET dynamic images. The whole tumor radioactivity was calculated based on each plane's tumor ROI. The transport constant from plasma to tissue (Ki) that is related to BBB permeability was estimated by a two-compartmental model. The PET-MRI registration method developed by Lin et al was found to work well for Ga-68 PET-MRI image registration. Estimated whole tumor K$-i$/ was 0.0002 $POM 0.0019 (s.d.)ml/min/g for the baseline study and was increased by 46 $POM 42 (s.d.)% with RMP7.!3
机译:摘要:为研究缓激肽类似物RMP7对脑肿瘤患者血脑屏障通透性变化的影响,使用Ga-68 EDTA PET定量测定肿瘤组织通透性,进行两次动态Ga-68 EDTA PET扫描(有无RMP7) )对每个患者进行。两次扫描结果之间的变化用于评估药物的效果。还进行了MRI以提供解剖学信息。动态PET研究期间的患者运动通过逐帧PET图像配准得到纠正。由于PET和MRI图像之间的方向不同,所有PET图像都与相应患者的MRI图像共同配准。将动态扫描的所有帧相加,然后再注册到MRI图像。登记的主要特征是颅骨和肿瘤的边界。配准后,在MRI图像上定义了感兴趣的区域(ROI),并将其复制到配准的PET动态图像中。基于每个平面的肿瘤ROI计算整个肿瘤的放射性。与血浆血脑屏障通透性有关的从血浆到组织的运输常数(Ki)是由两室模型估算的。发现由Lin等人开发的PET-MRI配准方法对于Ga-68 PET-MRI图像配准非常有效。对于基线研究,估计的整个肿瘤K $ -i $ /为0.0002 $ POM 0.0019(s.d.)ml / min / g,而使用RMP7则增加了46 $ POM 42(s.d。)%。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号