首页> 外文会议>Optical and Imaging Techniques for Biomonitoring >Skin temperature profiles on the human chest and in the wrist area
【24h】

Skin temperature profiles on the human chest and in the wrist area

机译:人胸部和腕部区域的皮肤温度曲线

获取原文

摘要

Abstract: Skin temperatures on the chest and in the wrist area are interesting for continuous monitoring because they can be easily instrumented using an elastic belt or wristband which do not hamper movement in sports, for example. An infrared thermograph camera and NTC thermistors were used to take temperature profiles at these sensing points with a resolution of 0.1 degrees Celsius, and colored thermograms were used to analyze and compare the results. The effect of environmental changes on the skin temperature in the wrist area was studied by cooling and heating the fingers in water at 10 degrees Celsius and 40 degrees Celsius, and the effects of a loading situation on the chest area and wrist area were tested by means of a 30 min bicycle ergometer exercise. NTC thermistors were also used to measure wrist and chest temperatures in two environmental tests at minus 10 degrees Celsius and plus 60 degrees Celsius. Cooling of the fingers naturally reduces the skin temperature in the wrist area and heating increases it due to the venous circulation. The area of the radial artery in the wrist seems to be the most stable temperature point, altering by only about 2 degrees Celsius, whereas the temperature change at other points is up to 4 degrees Celsius. The bicycle ergometer exercise caused a decrease in skin temperature on the chest because of sweating. At the same time the skin temperature on the wrist decreased by about 1.5 degrees Celsius after the first 20 minutes and then returned to its previous level. The area of the radial artery in the wrist seems to be an attractive point for continuous temperature monitoring, especially under normal conditions, and also seems to reflect body temperature quite well upon loading and under different environmental conditions. !3
机译:摘要:连续监测胸部和腕部区域的皮肤温度很有趣,因为可以使用不妨碍运动运动的松紧带或腕带轻松地对它们进行测量。使用红外热像仪相机和NTC热敏电阻来获取这些感测点的温度曲线,分辨率为0.1摄氏度,并使用彩色热谱图分析和比较结果。通过在10摄氏度和40摄氏度的水中冷却和加热手指,研究了环境变化对腕部区域皮肤温度的影响,并通过以下方法测试了负荷情况对胸部和腕部区域的影响: 30分钟的自行车测功机锻炼。 NTC热敏电阻还用于在两次环境测试中分别在负10摄氏度和正60摄氏度下测量手腕和胸部的温度。手指的冷却自然会降低腕部区域的皮肤温度,而由于静脉循环,加热会使温度升高。腕部the动脉的区域似乎是最稳定的温度点,仅改变了约2摄氏度,而其他点的温度变化则高达4摄氏度。自行车测功计运动是由于出汗导致胸部皮肤温度降低。同时,手腕上的皮肤温度在前20分钟后下降了约1.5摄氏度,然后又恢复到之前的水平。手腕中的radial动脉区域似乎是连续监测温度的一个诱人点,尤其是在正常情况下,并且似乎在负载和不同环境条件下也能很好地反映体温。 !3

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号