The redundancy mechanisms of the Ariane 5 Operational Control Center

机译:Ariane 5操作控制中心的冗余机制

获取原文

摘要

The Operational Control Center represents the largest component in the Ariane 5 ground segment. It handles all interface management between the Ariane launcher and ground facilities during launch preparation phases. It ensures information exchange between on-board equipment and the ground, and controls the launch count-down. The control center is a real-time system distributed on four sites and linked with an optical fiber network. For safety and availability reasons, redundancy has been applied to most of the control center's subsystems: front-end equipment, processing units, networks. The design and development of the Ariane 5 control center was a challenge for several reasons: the safety and operational constraints; the compatibility with the test benches without redundancy used at earlier stages of the development cycle; the fully distributed architecture; the need for online repair and re-insertion of failed redundant units without interrupting the launch countdown.
机译:运营控制中心是Ariane 5地面部分最大的组成部分。它在发射准备阶段处理Ariane发射器与地面设施之间的所有接口管理。它确保了车载设备与地面之间的信息交换,并控制了发射的倒数计时。控制中心是一个实时系统,分布在四个站点上,并与光纤网络相连。出于安全性和可用性的原因,冗余已应用于大多数控制中心的子系统:前端设备,处理单元,网络。由于以下几个原因,Ariane 5控制中心的设计和开发面临着挑战:安全和操作方面的限制;与测试平台的兼容性,在开发周期的早期阶段没有冗余;完全分布式的架构;在不中断启动倒计时的情况下,需要在线维修和重新插入发生故障的冗余单元。