Abstract: The purpose of this study was to evaluate the raster photogrammetry based Corneal Topography System by determining: inter-operator variability, reproducibility of images, effects of defocused and decentered images, and the precision of data at different optical zones. 4 human cadaver eyes were used to study the inter-operator variability. To study the reproducibility of images, 3 human cadaver eyes and a test surface doped with flourescine (provided by PAR Vision Systems Corporation) were focused and their images taken four successive times. Defocused and decentered images were taken of 4 human cadaver eyes and four times of the test surface mentioned above. The precision of defocused/decentered cadaver eyes was evaluated at the following optical zones: 3 mm, 4 mm, 5 mm, and 6 mm. All human cadaver eyes used in the above experiments had their epithelial layer removed before imaging. Average inter-operator variability was 0.06 D. In reproducibility attempts, there was an average deviation of 0.28 D for the human cadaver eyes and 0.04 D for the test surface. The defocused and decentered test surface gave an average deviation of 0.09 D. Defocused and decentered cadaver eyes resulted in an average deviation of 0.52 D, 0.37 D, 0.24 D, and 0.22 D at optical zones of 3 mm, 4 mm, 5 mm, and 6 mm, respectively. The imaging method employed by PAR Vision Systems Corporation virtually eliminates inter-operator variability. The PAR Corneal Topography System's clinical usefulness, however, could be improved by improving the reproducibility of images, decreasing the sensitivity to spatial alignment, and increasing accuracy over smaller optical zones.!9
机译:摘要:这项研究的目的是通过确定以下因素来评估基于光栅摄影测量的角膜地形图系统:操作员之间的变异性,图像的可再现性,散焦和偏心图像的影响以及不同光学区域的数据精度。使用四只人类尸体眼睛来研究操作者之间的变异性。为了研究图像的可再现性,对三只尸体眼睛和掺有粉剂的测试表面(由PAR Vision Systems Corporation提供)进行聚焦,并连续四次拍摄图像。用四只人体尸体眼睛和上述测试表面的四倍拍摄散焦和偏心图像。在以下光学区域评估散焦/偏心尸体眼睛的精度:3 mm,4 mm,5 mm和6 mm。在上述实验中使用的所有人类尸体眼睛在成像之前都去除了它们的上皮层。操作员之间的平均差异为0.06D。在重现性尝试中,人尸眼的平均偏差为0.28 D,测试表面的平均偏差为0.04D。散焦和偏心的测试表面的平均偏差为0.09D。散焦和偏心的尸体眼睛在3 mm,4 mm,5 mm的光学区域上的平均偏差为0.52 D,0.37 D,0.24 D和0.22D。和6毫米。 PAR视觉系统公司采用的成像方法实际上消除了操作员之间的差异。但是,可以通过改善图像的可再现性,降低对空间对准的灵敏度并提高在较小光学区域的准确性来提高PAR角膜地形图系统的临床实用性!9

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号