When induction machines are fed by fast switching inverters, their interturn insulation is electrically more stressed than in the conventional feed. When inverters are used steep voltage pulses of high repetition frequency occur. This can cause partial discharges (PDs) leading to insulation failure. The PD inception voltage and velocity of the resulting electrical ageing depend on the voltage characteristic, insulation design and temperature. These relations were investigated using laboratory models of interturn insulation, semiconductor-based pulse generator and as PD detector an UV-sensitive photo multiplier tube.
机译:当感应电机由快速开关逆变器供电时,其匝间绝缘在电气上比传统的供电设备承受更大的压力。使用逆变器时,会出现高重复频率的陡峭电压脉冲。这可能会导致局部放电(PDs),从而导致绝缘故障。 PD起始电压和最终电老化的速度取决于电压特性,绝缘设计和温度。使用匝间绝缘,基于半导体的脉冲发生器以及紫外线敏感的光电倍增管作为PD检测器的实验室模型研究了这些关系。