Low frequency oscillations occurring in a power system can be accentuated in generators through a feedback loop which connects the output of the system to the summing junction of the automatic voltage regulator (AVR) where the power system stabilizer (PSS) is also connected. A method of decoupling these oscillations without compromising the benevolent effects of other control loops in that system is presented. A notch filter, located in the forward path of the negative damping signal, provides the necessary dynamic gain reduction (DGR) for switching off the detrimental signals. Relevant frequency domain analysis of the closed loop transfer function of a typical power system is provided which reflects the effect of tie-line disturbances on power angle oscillations. This leads to a restructuring of the transfer blocks in the system and the design of a DGR block that allows the decoupling of the negative damping signals. Additional insight into the effect of negative damping signals and their subsequent decoupling is provided through the examination of loop and transfer block signals.
机译:电力系统中发生的低频振荡可通过反馈环路在发电机中加重,该反馈环路将系统的输出连接到自动稳压器(AVR)的求和结点,其中自动稳压器(P​​SS)也已连接到该求和结点。提出了一种在不影响该系统中其他控制回路的仁慈效果的情况下对这些振荡进行解耦的方法。位于负阻尼信号正向路径中的陷波滤波器为关闭有害信号提供了必要的动态增益降低(DGR)。提供了典型电力系统闭环传递函数的相关频域分析,该分析反映了联络线干扰对功率角振荡的影响。这导致系统中传输块的重组以及DGR块的设计,DGR块允许负阻尼信号去耦。通过检查环路和传输块信号,可以进一步了解负阻尼信号及其后续去耦的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号