The results of comparing two potentiostat designs are presented. One is based on conventional use of a current-to-voltage converter (CVC); the second is a new design which employs a voltage-controlled current source (VCCS). The performance of the two designs in the time and frequency domains and the signal-to-noise ratio have been characterized. In the VCCS-type potentiostat, instabilities created by the CVC are eliminated. The working electrode of the gas sensor can now be connected directly to ground, improving the signal-to-noise ratio when long cables are used. The VCCS is controlled by the error voltage developed by a difference amplifier that compares the sensor bias voltage between the difference and working electrodes to a preset reference voltage. The VCCS is used to drive the counter electrode to maintain this bias level. Since the error voltage is proportional to the current in the sensor, the error voltage provides a nonintrusive measurement of current.
机译:给出了比较两种恒电位仪设计的结果。一种基于电流-电压转换器(CVC)的常规使用;另一种基于电流-电压转换器(CVC)。第二个是采用电压控制电流源(VCCS)的新设计。表征了两种设计在时域和频域的性能以及信噪比。在VCCS型恒电位仪中,消除了CVC产生的不稳定性。气体传感器的工作电极现在可以直接接地,从而在使用长电缆时提高了信噪比。 VCCS由差动放大器产生的误差电压控制,该误差电压将差动电极和工作电极之间的传感器偏置电压与预设参考电压进行比较。 VCCS用于驱动反电极以维持该偏置水平。由于误差电压与传感器中的电流成正比,因此误差电压提供了电流的非侵入式测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号