摘要

Reviews extensive data on both environmental testing and life testing (greater than one-million device hours of biased aging) of thermoelectric coolers (TECs) and discusses the dominant failure modes possible during a typical 20-year lifetime. Results indicate that the proper procurement, packaging, and screening of TECs can provide failure rates much less than the 1300 FITs quoted by Bellcore. The overall reliability of standard 18 couple TECs installed in the Astrotec Laser Module are found to be 359 FITs at 10 years, assuming a 40 degrees C T/sub HOT/ and a 20 degrees C Delta T. The random failure rate is 140 FITs at 60% confidence limit based on laboratory aging data alone.
机译:回顾有关热电冷却器(TEC)的环境测试和寿命测试(超过100万设备小时的有偏老化)的大量数据,并讨论在典型的20年使用寿命中可能出现的主要故障模式。结果表明,对TEC进行适当的采购,包装和筛选可以提供的故障率比Bellcore引用的1300 FIT少得多。在40年CT / sub HOT /和20摄氏度Delta T的条件下,在Astrotec激光模块中安装的标准18对TEC的整体可靠性在10年时为359 FIT。在60°C时,随机故障率为140 FIT仅基于实验室老化数据的置信限百分比。