EXPERIMENTAL STUDY ON AIR SEASONAL THERMAL STORAGE IN A GROUND SOURCE HEAT PUMP SYSTEM IN SEVERE COLD AREAS

机译:严重寒冷地区地下源热泵系统中空气季节性热储存的试验研究

获取原文

摘要

In view of the problem of the ground load imbalance in severe cold area, this paper puts forward a ground source heat pump system with air seasonal thermal storage (GSHPASTS), and presents the experimental study of air seasonal heat storage in Harbin. The nature air heat was injected into the soil in summer and extracted by the heat pump in winter. The results show that the average performance coefficient of the heat storage was 12.44, and the heat storage rate of unit buried depth was 14.20W/m. After the soil recovery for 69 days, the average temperature of the soil around the ground heat exchanger (GHE) was about 1°C higher than that of the soil in the observational well. Therefore, it can be concluded that the idea of air seasonal heat storage is feasible, and the intermittent operation is helpful to improve the heat storage performance.
机译:鉴于严重寒冷地区的地面负荷不平衡问题,本文提出了一种带空气季节性热储存(GSHPATTS)的地源热泵系统,并提出了哈尔滨空气季节性蓄热的实验研究。本质空气热量在夏季注入土壤中,并在冬季用热泵提取。结果表明,蓄热量的平均性能系数为12.44,单位埋藏深度的蓄热速率为14.20W / m。在土壤回收率69天后,地面热交换器(GHE)周围的土壤的平均温度约为1°C,比观察到井的土壤高约1°C。因此,可以得出结论,空气季节性蓄热的想法是可行的,并且间歇操作有助于提高蓄热性能。