Heat pumps utilizing variable-speed compressors and other capacity control techniques offer significant seasonal efficiency improvements over traditional single-speed systems by reducing system cycling losses and corresponding system inefficiencies. However, the majority of residential heat pumps operated in the United States (US) utilize single-speed Permanent Split Capacitor (PSC) compressors and offer few capacity control options. This paper presents testing results of a novel electronic drive that enables the variable-speed control of conventionally single-speed PSC motors in compressors and outdoor fans using a low power inverter. The focus of this research is to optimize the cooling seasonal performance of a 2-ton (6,7 kW) off-the-shelf residential air-source heat pump after replacing its PSC scroll compressor with a PSC rotary compressor with the low power inverter installed to enable variable speed control of the PSC motors. The modified heat pump has been tested in the Ray W. Herrick Laboratories at Purdue University for Seasonal Energy Efficiency Rating (SEER). The results show that a SEER improvement of nearly 32,85% is possible using a low power inverter for the compressor, indoor fan and outdoor fan. Results of this optimization indicate a total SEER improvement of 39,47% is possible by changing from a PSC scroll compressor to a PSC rotary compressor and connecting the inverter to these components.
机译:与传统的单速系统相比,利用变速压缩机和其他容量控制技术的热泵可通过减少系统循环损失和相应的系统效率低下来显着提高季节性效率。但是,在美国(US)运营的大多数住宅热泵都使用单速永久分流电容器(PSC)压缩机,并且几乎没有容量控制选项。本文介绍了一种新型电子驱动器的测试结果,该驱动器可使用低功率逆变器对压缩机和室外风扇中的传统单速PSC电动机进行变速控制。这项研究的重点是在用低功率逆变器将PSC涡旋压缩机替换为PSC旋转压缩机后,优化2吨(6,7 kW)的现成住宅空气源热泵的制冷季节性能。安装后可以对PSC电机进行变速控制。修改后的热泵已经在普渡大学的Ray W. Herrick实验室进行了季节性能效等级(SEER)测试。结果表明,对于压缩机,室内风扇和室外风扇,使用低功率逆变器可以将SEER改善近32.85%。优化结果表明,通过从PSC涡旋压缩机改为PSC旋转压缩机并将逆变器连接到这些组件,可以将SEER总体提高39.47%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号