Annual Performance of a Two-Speed Dedicated Dehumidification Heat Pump in the NIST Net-Zero Energy Residential Test Facility

机译:NIST净零能耗住宅测试设施中两速专用除湿热泵的年度性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A 2715 ft2 (252 m2), two story, residential home of the style typical of the Gaithersburg, Maryland area was constructed in 2012 to demonstrate technologies for net-zero energy (NZE) homes (or ZEH). The NIST Net-Zero Energy Residential Test Facility (NZERTF) functions as a laboratory to support the development and adoption of cost-effective NZE designs, technologies, construction methods, and building codes. The primary design goal was to meet the comfort and functional needs of the simulated occupants. The first annual test period began on July 1, 2013 and ended June 30, 2014. During the first year of operation, the home's annual energy consumption was 13039 kWh (4.8 kWh ft-2, 51.7 kWh m-2), and the 10.2 kW solar photovoltaic system generated an excess of 484 kWh. During this period the heating and air conditioning of the home was performed by a novel air-source heat pump that utilized a reheat heat exchanger to allow hot compressor discharge gas to reheat the supply air during a dedicated dehumidification mode. During dedicated dehumidification, room temperature air was supplied to the living space until the relative humidity setpoint of 50% was satisfied. The heat pump consumed a total of 6225 kWh (2.3 kWh ft-2, 24.7 kWh m-2) of electrical energy for cooling, heating, and dehumidification. Annual cooling efficiency was 10.1 Btu W-1h-1 (2.95 W W-1), relative to the rated SEER of the heat pump of 15.8 Btu W-1h-1 (4.63 W W-1). Annual heating efficiency was 7.10 Btu W-1h-1 (2.09 W W-1), compared with the unit's rated HSPF of 9.05 Btu W-1h-1 (2.65 W W-1). These field measured efficiency numbers include dedicated dehumidification operation and standby energy use for the year. Annual sensible heat ratio was approximately 70%. Standby energy consumption was 5.2 % and 3.5 % of the total electrical energy used for cooling and heating, respectively.
机译:2012年建造了2715英尺 2 (252 m 2 )两层楼的住宅,具有马里兰州盖瑟斯堡地区的典型风格,以演示零净技术能源(NZE)房屋(或ZEH)。 NIST净零能耗住宅测试设施(NZERTF)充当实验室,以支持开发和采用具有成本效益的NZE设计,技术,构造方法和建筑规范。主要设计目标是满足模拟乘员的舒适性和功能需求。第一个年度测试期始于2013年7月1日,至2014年6月30日止。在运营的第一年,房屋的年度能耗为13039 kWh(4.8 kWh ft -2 ,51.7 kWh -2 ),而10.2 kW的太阳能光伏系统产生了超过484 kWh的电量。在此期间,住宅的供暖和空调是通过新型空气源热泵进行的,该空气源利用再热热交换器使热压缩机排出的气体在专用除湿模式下对供气进行再热。在专用除湿期间,将室温空气供应到居住空间,直到满足50%的相对湿度设定值。热泵总共消耗了6225 kWh(2.3 kWh ft -2 24.7 kWh m -2 )的电能用于冷却,加热和除湿。相对于热泵的额定SEER,年冷却效率为10.1 Btu W -1 h -1 (2.95 WW -1 ) 15.8 Btu W -1 h -1 (4.63 WW -1 )。年供热效率为7.10 Btu W -1 h -1 (2.09 WW -1 ),而单位的额定HSPF为9.05 Btu W -1 h -1 (2.65 WW -1 )。这些现场测得的效率数字包括当年专用的除湿运行和待机能耗。年显热率约为70%。待机能耗分别为用于冷却和加热的总电能的5.2%和3.5%。

著录项

  • 期刊名称 other
  • 作者

    W. Vance Payne;

  • 作者单位
  • 年(卷),期 -1(2016),WINTER CONFERENCE
  • 年度 -1
  • 页码 OR-16-C040
  • 总页数 16
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号