首页> 外文会议>IEEE Photovoltaic Specialists Conference >Suggested Modifications for Bifacial Capacity Testing
【24h】

Suggested Modifications for Bifacial Capacity Testing

机译:双面容量测试的建议修改

获取原文

摘要

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of photovoltaic systems. With the increasing deployment of bifacial photovoltaic modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error were inherently higher for the measured capacity of bifacial systems, they could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance—either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2–10-month observation period. Capacity test accuracy could be improved further by using the measured back-of-module temperature and the IEC 61724-2 test method for well curated systems.
机译:诸如ASTM 2848和IEC 61724-2中所述的容量测试在光伏系统的合同和验收测试中被广泛使用。随着双面光伏模块的部署不断增加,需要开发一种标准化方法来对这些系统进行容量测试。尽管对于双面系统的测量容量而言,变异性和偏差误差本来就较高,但可以通过适当地合并后照度(测量或建模)将其降低到与单面参考系统一致的水平。三个现场安装提供了双面系统的容量,在2-10个月的观察期内,平均偏差和标准偏差均在1%以内。通过使用测得的模块背面温度和针对精心挑选的系统的IEC 61724-2测试方法,可以进一步提高容量测试的准确性。