首页> 外文会议>International symposium on high voltage engineering >Condition Assessment of Underground Cable System Using Health Index and Conditional Multiplying Factor
【24h】

Condition Assessment of Underground Cable System Using Health Index and Conditional Multiplying Factor

机译:基于健康指数和条件乘数的地下电缆系统状态评估

获取原文
获取外文期刊封面目录资料

摘要

This paper presents condition assessment of underground cable system for an independent power producer in Thailand. The underground cable is very important in both underground transmission and distribution system. Nowadays, the underground cable system is widely utilized to improve system reliability and aesthetic view. When cables have been used for a period of time, they become deteriorated and finally damaged because of electrical and mechanical stresses, and etc. If the failures were not recognized and repaired in time, the catastrophic failure could probably occur. Furthermore, this affects to customer's reliability and trustworthy. Therefore, the condition assessment and health index calculation are needed to effectively maintain the system. The underground cable system consists of power cable, termination, joint, manhole, and duct bank. Normally, visual inspection and special testing with those components are required for assessment. Without power interruption, on-line testing consists of visual inspection, infrared thermography inspection and partial discharge measurement. The off-line testing, which is performed during maintenance, consists of polarization index measurement, dissipation factor measurement, leakage current measurement and very low frequency withstand test as required. These testing methods are considered together to evaluate the actual condition of all components by using weighting and scoring method. A conditional factor, considering service year, load current, failure frequency, laying, and environment, is proposed to provide more accurate result in term of practical usage condition. The web-application software is applied to setup systematic database for technical data and test results. It has been developed for processing condition assessment and facilitating maintenance activities.
机译:本文介绍了泰国一家独立电力生产商的地下电缆系统的状态评估。地下电缆在地下输配电系统中都非常重要。如今,地下电缆系统已被广泛使用,以提高系统的可靠性和美观性。电缆使用一段时间后,由于电气和机械应力等原因,它们会变质并最终损坏。如果未能及时发现并修复故障,则可能会发生灾难性故障。此外,这影响了客户的可靠性和可信赖性。因此,需要条件评估和健康指标计算来有效地维护系统。地下电缆系统由电源电缆,端接,接头,人孔和管道组组成。通常,需要对这些组件进行外观检查和特殊测试才能进行评估。在不中断电源的情况下,在线测试包括外观检查,红外热像仪检查和局部放电测量。维护期间执行的离线测试包括极化指数测量,耗散因数测量,泄漏电流测量以及根据需要的极低频耐受性测试。将这些测试方法一起考虑,以使用加权和计分方法评估所有组件的实际状况。提出了一个考虑服务年限,负载电流,故障频率,铺设和环境的条件因素,以根据实际使用条件提供更准确的结果。该网络应用软件用于建立技术数据和测试结果的系统数据库。它被开发用于处理状态评估和促进维护活动。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号