The personal protective equipment (conductive suit) should decrease the power frequency electric field high levels up to occupational permissible limit values for human safety. The personal protective equipment screening property realized by conductive materials which has shielding coefficient. It is relevant for practice to develop test method of conductive suit and materials protection properties by direct power frequency electric field measurement. The paper presents the comparison of results shielding materials testing by different methods. There were compared data of direct power frequency electric field measurement and standard test method according to IEC 60895. The suggested shielding efficiency test method was based on electric field strength measurements inside the metal holder covered by materials test sample placed in high level power frequency electric field. 14 test samples of protective suit textile with use two methods was compared. The results obtained by both methods were analyzed by means of linear approximation function as a correlation between suggested and standard test methods. This function defined minimal shielding efficiency requirements for conductive material of power frequency electric field personal protective equipment measured by suggested method. In prospect, the new method will allow conductive suits manufacturers to predict maximum possible power frequency electric field decrease for compliance with permissible limit values at workplaces. Therefore, the suggested method of shielding efficiency assessment is nearest to standardization in hygienic practice and control at workplaces parameter.
机译:个人防护设备(导电服)应将工频电场的强度降低至职业安全极限值,以确保人身安全。具有屏蔽系数的导电材料可实现个人防护装备的屏蔽性能。通过直接工频电场测量来开发导电服和材料保护性能的测试方法对实践具有重要意义。本文介绍了不同方法对屏蔽材料测试结果的比较。比较了直接工频电场测量和根据IEC 60895的标准测试方法的数据。建议的屏蔽效率测试方法基于放置在高工频电场中的材料测试样品覆盖的金属支架内部的电场强度测量。比较了使用两种方法的防护服纺织品的14个测试样品。通过线性逼近函数分析这两种方法获得的结果,作为建议的测试方法与标准测试方法之间的相关性。此功能定义了通过建议方法测量的工频电场个人防护设备的导电材料的最小屏蔽效率要求。展望未来,新方法将使导电服制造商能够预测最大可能的工频电场降低,以符合工作场所允许的极限值。因此,建议的屏蔽效率评估方法最接近卫生实践中的标准化和工作场所参数控制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号