This paper compares an in-house dielectric properties measurement system based on the "Stuchly and Stuchly" method with the broadly commercialised Keysight setup and existing literature for the characterization of ablated and non-ablated liver tissue. Measurements were carried out on ex-vivo ovine liver tissue across the frequency range 0.5 - 4.5 GHz. Results show that the in-house "Stuchly & Stuchly" method using calibration standards such as deionised water, methanol and open-circuit conditions, offers comparable performance to the proprietary Keysight system. Moreover, results are also comparable to measurements at 2.45 GHz documented in the literature. Being the in-house system suitable for portable setups as reported in the literature, this study shows that measurement of dielectric properties of tissue can be performed even during the thermal ablation procedure.
机译:本文将基于“ Stuchly and Stuchly”方法的室内介电特性测量系统与广泛商业化的Keysight设置以及现有的用于消融和未消融肝组织表征的文献进行了比较。在0.5-4.5 GHz频率范围内对离体绵羊肝脏组织进行测量。结果表明,使用诸如去离子水,甲醇和断路条件等校准标准的内部“ Stuchly&Stuchly”方法可提供与专有Keysight系统相当的性能。此外,结果也可与文献中记载的在2.45 GHz的测量结果相媲美。作为文献中报道的适合便携式设备的内部系统,这项研究表明,即使在热消融过程中,也可以进行组织介电性能的测量。