Movable fire load survey for old residential highrise buildings in Hong Kong

机译:香港老住宅高层建筑的可移动火灾负荷调查

获取原文

摘要

The fire safety of existing highrise residential buildings in Hong Kong over thirty-five years old is a concern. These buildings used to have high occupancies but with far fewer fire safety provisions than those specified in current fire codes. To understand the potential fire risk behind the old existing buildings, fire load density should be surveyed first. A sample of eight such old highrise buildings was selected and surveyed. Both fixed and movable fire loads were reviewed. Fire load density was found to be high due to excess storage of domestic fuel. Movable fire load in cage houses is a concern. Four of the eight surveyed buildings have fire load density over the upper limit specified in the code. Fire risks associated with storing too many combustibles were also studied. With such a high content of combustibles, it is more likely that big accidental fires will happen. Finally, occupant loading in each example building was also surveyed. This would provide important information for working out the evacuation strategy.
机译:香港现有高层住宅建筑的火灾安全是一个关注的问题。这些建筑用于具有高占用,但远远超过当前消防码中规定的较少的消防安全规定。要了解旧现有建筑物背后的潜在火灾风险,应首先调查火灾负荷密度。选择并调查了八大旧高层建筑的样本。修复了固定和可移动的火焰载量。由于国内燃料的过剩储存,发现火焰负荷密度很高。笼式房屋中的可移动火焰负荷是一个令人担忧的问题。八个受测量建筑中的四个具有在代码中指定的上限上的火力载密度。还研究了与储存太多可燃物相关的防火风险。利用如此高的可燃物,更有可能发生大型意外火灾。最后,调查了每个示例建筑物的乘员装载。这将提供用于制定疏散策略的重要信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号