As an essential component of power transformer, transformer bushing’s reliable operation does not only impact the safety of transformer itself but also other equipment located nearby. To prevent bushing failures, it is therefore important to routinely assess bushing insulation and pin-point the potential problem as early as possible. In this paper, fault diagnosis and tear-down analysis of five 500kV oil-impregnated paper (OIP) transformer bushings are presented. Results of different field and laboratory diagnostic tests are discussed and compared. Key features of partial discharge-led defect with x-wax deposits are analysed. The effectiveness of adopting frequency domain spectroscopy (FDS) in combination with dissolved gas analysis (DGA) as supplementary field diagnostic test is then demonstrated.
机译:作为电力变压器的重要组成部分,变压器套管的可靠运行不仅会影响变压器本身的安全,还会影响附近的其他设备。为了防止套管故障,因此重要的是定期评估套管绝缘并尽早指出潜在问题。本文介绍了五个500kV油浸纸(OIP)变压器套管的故障诊断和拆除分析。讨论并比较了不同现场和实验室诊断测试的结果。分析了具有x-蜡沉积物的局部放电缺陷的关键特征。然后证明了采用频域光谱法(FDS)结合溶解气体分析(DGA)作为补充现场诊断测试的有效性。