首页> 外文会议>IEEE Conference on Energy Internet and Energy System Integration >Analysis of Broken Lines at Overhead Ground Wire and Pre-twisted Wire Port Based on Skin Effect
【24h】

Analysis of Broken Lines at Overhead Ground Wire and Pre-twisted Wire Port Based on Skin Effect

机译:基于趋肤效应的架空地线和预绞线端口断线分析

获取原文

摘要

Breakage and stock breaks are caused by the pre-twisted wire fittings of lightning protection lines in overhead transmission lines with power outages and even secondary disasters. In order to ensure the normal and stable operation of the power grid and reduce the wire breakage accident, it is studied that the heat generation of the overhead ground wire and the pre-twisted wire contact port in the paper. The ground wire and the pre-twisted wire contact point are equivalent to a uniform cylindrical conductive bridge, and the simulation model of the pre-twisted wire contact port is established. The radial and axial current density distribution curves of the grounding wire under the influence of the skin effect are analyzed, and the influence of current density on the contact resistance is studied. The key factor in influencing the contact resistance is the relative permeability of the material, and effective improvement measures are proposed accordingly.
机译:断线和断线是由于架空输电线路中的避雷线的预绞线配件造成停电甚至二次灾难而引起的。为了保证电网的正常,稳定运行并减少断线事故,本文对架空地线和预绞线接触口的发热进行了研究。地线和预绞线接触点等效为均匀的圆柱形导电桥,建立了预绞线接触端口的仿真模型。分析了趋肤效应影响下接地线的径向和轴向电流密度分布曲线,研究了电流密度对接触电阻的影响。影响接触电阻的关键因素是材料的相对磁导率,并提出了有效的改进措施。