首页> 外文会议>IEEE Conference on Energy Internet and Energy System Integration >Analysis of Broken Lines at Overhead Ground Wire and Pre-twisted Wire Port Based on Skin Effect
【24h】

Analysis of Broken Lines at Overhead Ground Wire and Pre-twisted Wire Port Based on Skin Effect

机译:基于皮肤效应的架空接地线和预绞线端口断线分析

获取原文

摘要

Breakage and stock breaks are caused by the pre-twisted wire fittings of lightning protection lines in overhead transmission lines with power outages and even secondary disasters. In order to ensure the normal and stable operation of the power grid and reduce the wire breakage accident, it is studied that the heat generation of the overhead ground wire and the pre-twisted wire contact port in the paper. The ground wire and the pre-twisted wire contact point are equivalent to a uniform cylindrical conductive bridge, and the simulation model of the pre-twisted wire contact port is established. The radial and axial current density distribution curves of the grounding wire under the influence of the skin effect are analyzed, and the influence of current density on the contact resistance is studied. The key factor in influencing the contact resistance is the relative permeability of the material, and effective improvement measures are proposed accordingly.
机译:破损和股票休息是由避雷网线的预捻线配件引起的射频传输线,其具有停电甚至二次灾害。为了确保电网的正常和稳定运行并减少线断裂事故,研究了纸上的架空接地线的发热和预绞线接触口。接地线和预绞线接触点等同于均匀的圆柱形导电桥,并且建立了预绞线接触端口的仿真模型。分析了在皮肤效果的影响下接地线的径向和轴向电流密度分布曲线,研究了电流密度对接触电阻的影响。影响接触电阻的关键因素是材料的相对渗透性,因此提出了有效的改进措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号