This paper presents a 0.9m long capacitive force sensor for a catheter integration, which measures a contact force to inner vessel wall or organs with a resolution of 0.5gf. The force sensor is implemented with a thin flexible printed circuit board (FPCB) encapsulated by a force sensitive medium, multilayer polydimethylsiloxane (PDMS). The parasitic capacitance (CP) inherent in long catheters significantly degrades the sensing accuracy of capacitive force sensors. To account for this, this work proposes a sensor interface with CP canceller. By removing the 348pF (91.5%) of CP with the CP canceller, the capacitive force sensor achieves a capacitance resolution of 16aF equivalent to a force error of 0.5gf, which is a 10× improvement compared to the conventional sensor interface. The proposed force sensor offers great potential for real-time force monitoring of cardiovascular surgery.
机译:本文提出了一种0.9m长的用于导管集成的电容力传感器,该传感器可测量分辨率为0.5gf的与血管内壁或器官的接触力。力传感器由薄的柔性印刷电路板(FPCB)实施,该印刷电路板由力敏感介质,多层聚二甲基硅氧烷(PDMS)封装。长导管中固有的寄生电容(CP)大大降低了电容式力传感器的传感精度。为了解决这个问题,这项工作提出了带有CP消除器的传感器接口。通过使用CP消除器消除348pF(91.5%)的CP,电容式力传感器实现了16aF的电容分辨率,相当于0.5gf的力误差,与传统传感器接口相比,提高了10倍。提出的力传感器为心血管手术的实时力监测提供了巨大的潜力。