The grid integration of a photovoltaic park requires some rules to be fulfilled, rules stipulated in local normative. One of the common constraint is the voltage and reactive power control. In some cases this could lead to dangerous transient phenomena, associated with overvoltages and current circulations. In this paper such a scenario is discussed showing not only the causes and effects, but also some recommendation to avoid possible damages, based on oscillograms recorded by digital protective relays.
机译:光伏园区的电网整合需要满足一些规则,这些规则是当地规范中规定的。常见约束之一是电压和无功功率控制。在某些情况下,这可能会导致危险的瞬态现象,与过电压和电流环流相关。本文讨论了这种情况,它不仅显示了原因和结果,而且还提出了一些建议,这些建议基于数字保护继电器记录的波形图来避免可能的损坏。