首页> 外文会议>Chinese Control and Decision Conference >Online determination method of power system fault chains based on the bus load rate
【24h】

Online determination method of power system fault chains based on the bus load rate

机译:基于母线负荷率的电力系统故障链在线确定方法

获取原文

摘要

Fault chain model, the basis of risk assessment and prevention control, is used to avoid cascading outages. In this paper, a new fault chain model is established. The fault chain, calculated by this fault chain model, is consisted of the initial segment and the middle segment. The index of bus load rate for the initial and the middle segments is presented firstly to reflect the load condition of a system in the fault chain model. Then, other indices, such as historical fault statistics, line load degree, and correlation coefficient in the initial segment and power flow transfer, sequent overload of lines, and damage of transmission sections in the middle segment, are concerned and normalized to predict all the fault chains. Besides, the maximizing deviations method is used to calculate the weight of index. Finally, the rationality of the proposed fault chain model is demonstrated via New England 39 bus system.
机译:故障链模型是风险评估和预防控制的基础,可避免级联中断。本文建立了一种新的故障链模型。由该故障链模型计算出的故障链由初始段和中间段组成。在故障链模型中,首先给出了母线段初始和中间段的负荷率指标,以反映系统的负荷情况。然后,将其他指标(例如历史故障统计信息,线路负荷程度以及初始网段和潮流传递中的相关系数,线路的后续过载以及中间网段的传输段的损坏)相关联并进行归一化以预测所有断链。另外,采用最大偏差法计算指标权重。最后,通过新英格兰39总线系统证明了所提出的故障链模型的合理性。