首页> 外文会议>IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems >NiyanTron — An approach to develop a control system app for data center cooling
【24h】

NiyanTron — An approach to develop a control system app for data center cooling

机译:NiyanTron —一种开发用于数据中心冷却的控制系统应用程序的方法

获取原文

摘要

This study addresses a Data Center Cooling Control System App designed and developed to make the existing technology modular and economical. The project has been carried out using standard lab equipment and software. The emphasis of the study is on conditioning the outside air by using the cooling systems that aren't energy intensive and hence reduce the overall cost of operation. The paper also discusses the results, cost analysis and future scope while implementing this niche technology. The app is titled 'NiyanTron', a portmanteau of the Hindi word Niyantran meaning control and elecTRONic, as the app is an electronic control system. The study was carried out for environmental conditions in four cities - Albuquerque, NM, Dallas, TX, Chicago, IL and Tucson, AZ. The weather information from the four regions was used as the preliminary data to run the control system and show the versatility of the app. The modes Economizer and Return Air cooling have been used for Chicago and Dallas. Tucson and Albuquerque have Direct Evaporative Cooling and Economizer mode. Further, the use of Glassdek and Celdek media has been compared.
机译:这项研究致力于设计和开发一个数据中心冷却控制系统应用程序,以使现有技术模块化且经济。该项目已使用标准实验室设备和软件进行。该研究的重点是通过使用不耗能的冷却系统来调节外部空气,从而降低总体运行成本。本文还讨论了实施该细分技术时的结果,成本分析和未来范围。该应用程序的名称为“ NiyanTron”,它是北印度语单词Niyantran的portmanteau,意为控制和电子,因为该应用程序是一个电子控制系统。该研究针对四个城市的环境条件进行了研究-新墨西哥州的阿尔伯克基,德克萨斯州的达拉斯,伊利诺伊州的芝加哥和亚利桑那州的图森。来自四个地区的天气信息被用作运行控制系统的初步数据,并显示了该应用程序的多功能性。省煤器和回风冷却模式已用于芝加哥和达拉斯。 Tucson和Albuquerque具有直接蒸发冷却和省煤器模式。此外,已经比较了Glassdek和Celdek介质的使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号