This study addresses a Data Center Cooling Control System App designed and developed to make the existing technology modular and economical. The project has been carried out using standard lab equipment and software. The emphasis of the study is on conditioning the outside air by using the cooling systems that aren't energy intensive and hence reduce the overall cost of operation. The paper also discusses the results, cost analysis and future scope while implementing this niche technology. The app is titled 'NiyanTron', a portmanteau of the Hindi word Niyantran meaning control and elecTRONic, as the app is an electronic control system. The study was carried out for environmental conditions in four cities - Albuquerque, NM, Dallas, TX, Chicago, IL and Tucson, AZ. The weather information from the four regions was used as the preliminary data to run the control system and show the versatility of the app. The modes Economizer and Return Air cooling have been used for Chicago and Dallas. Tucson and Albuquerque have Direct Evaporative Cooling and Economizer mode. Further, the use of Glassdek and Celdek media has been compared.
机译:本研究解决了设计和开发的数据中心冷却控制系统应用,以使现有技术模块化和经济。该项目已使用标准实验室设备和软件进行。该研究的重点是通过使用没有能量密集的冷却系统调节外部空气,从而降低整体操作成本。本文还讨论了实施此利基技术的同时探讨了结果,成本分析和未来范围。该应用程序标题为“Niyantron”,是印地语Word Niyantran的Portmanteau,意思是控制和电子,因为该应用是一种电子控制系统。该研究是在四个城市的环境条件下进行 - Albuquerque,NM,达拉斯,TX,芝加哥,IL和图森,AZ。从四个区域的天气信息被用作运行控制系统的初步数据并显示应用程序的多功能性。模型节能器和返回空气冷却已用于芝加哥和达拉斯。图森和阿尔伯克基具有直接的蒸发冷却和经济化器模式。此外,已经比较了Glassdek和Celdek介质的使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号