摘要

In this paper an interface circuit for MOX gas sensor is presented. It is based on a resistance-to-frequency converter and improves existing solutions in term of performance (offset) and power efficiency. The resistive range covered is 100Ω-1MΩ, with an equivalent 8-bit precision in a total measurement time of 1 second. This corresponds to a dynamic range of about 128dB. Power consumption and design strategy are optimized for mass production targeting consumer applications. The interface is implemented in a standard CMOS 130nm technology with an area of 125000μm and 450μA of current consumption.
机译:本文提出了一种用于MOX气体传感器的接口电路。它基于电阻-频率转换器,并且在性能(偏移)和功率效率方面改进了现有解决方案。覆盖的电阻范围为100Ω-1MΩ,在1秒的总测量时间内具有等效的8位精度。这对应于约128dB的动态范围。功耗和设计策略已针对面向消费类应用的批量生产进行了优化。该接口采用标准CMOS 130nm技术实现,面积为125000μm,电流消耗为450μA。