首页> 外文会议>International Conference on Electrical Machines >Detection of short circuits between stator laminations of electrical machine by analysis of external magnetic field
【24h】

Detection of short circuits between stator laminations of electrical machine by analysis of external magnetic field

机译:通过外部磁场分析检测电机定子叠片之间的短路

获取原文

摘要

This paper presents the results of a research devoted to the detection of short circuits between stator laminations of electrical machine using external magnetic field. Experimental measurements lead one to display the influence of various phenomena on this magnetic field. It is shown that the surface currents due to burrs at the external surface of the machine have an important contribution compared to the increase of the eddy currents in the short circuit in the short circuit volume.
机译:本文介绍了使用外部磁场检测电机定子叠片之间的短路的研究的结果。实验测量引线呈现出各种现象对该磁场的影响。结果表明,与短路容积中短路中的短路中的涡流的增加相比,由于机器外表面的毛刺引起的表面电流具有重要贡献。