首页> 外文会议>International energy conversion engineering conference;AIAA propulsion and energy forum >Swift BAT Thermal Recovery After Loop Heat Pipe #0 Secondary Heater Controller Failure in October 2015
【24h】

Swift BAT Thermal Recovery After Loop Heat Pipe #0 Secondary Heater Controller Failure in October 2015

机译:2015年10月,回路0热管二次加热器控制器发生故障后,快速BAT热恢复

获取原文

摘要

The Swift BAT LHP #0 primary heater controller failed on March 31, 2010. It has been disabled. On October 31, 2015, the secondary heater controller of this LHP failed. On November 1, 2015, the LHP #0 CC temperature increased to as 18.6°C, despite that the secondary heater controller set point was 8.8°C. It caused the average DM XA1 temperature to increase to 25.9°C, which was 5°C warmer than nominal. As a result, the detectors became noisy. To solve this problem, the LHP #1 secondary heater controller set point was decreased in 0.5°C decrements to 2.2°C. The set-point decrease restored the average DM XA1 temperature to a nominal value of 19.7°C on November 21.
机译:Swift BAT LHP#0主加热器控制器在2010年3月31日发生故障。它已被禁用。 2015年10月31日,该LHP的辅助加热器控制器发生故障。 2015年11月1日,LHP#0 CC温度升高至18.6°C,尽管辅助加热器控制器的设定点为8.8°C。这导致DM XA1的平均温度升高到25.9°C,比正常温度高5°C。结果,检测器变得嘈杂。为了解决此问题,将LHP#1二级加热器控制器的设定点降低了0.5°C,降至2.2°C。设定点降低使11月21日的DM XA1平均温度恢复到19.7°C的标称值。