首页> 外文OA文献 >Thermal Vacuum/Balance Test Results of Swift BAT with Loop Heat Pipe Thermal System
【2h】

Thermal Vacuum/Balance Test Results of Swift BAT with Loop Heat Pipe Thermal System

机译:带回路热管热系统的Swift BAT的热真空/平衡测试结果

摘要

The Swift Burst Alert Telescope (BAT) Detector Array is thermally well coupled to eight constant conductance heat pipes (CCHPs) embedded in the Detector Array Plate PAP), and two loop heat pipes (LHPs) transport heat from the CCHPs to a radiator. The CCHPs have ammonia as the working fluid and the LHPs have propylene as the working fluid. Precision heater controllers, which have adjustable set points in flight, are used to control the LHP compensation chamber and Detector Array xA1 ASIC temperatures. The radiator has AZ-Tek's AZW-LA-II low solar absorptance white paint as the thermal coating, and is located on the anti-sun side of the spacecraft. A thermal balance (T/B) test on the BAT was successfully completed. It validated that the thermal design satisfies the temperature requirements of the BAT in the flight thermal environments. Instrument level and observatory level thermal vacuum (TN) cycling tests of the BAT Detector Array by using the LHP thermal system were successfully completed. This paper presents the results of the T/B test and T N cycling tests.
机译:快速爆炸警报望远镜(BAT)检测器阵列与嵌入在“检测器阵列板PAP”中的八个恒定电导率热管(CCHP)热耦合良好,并且两个回路热管(LHP)将热量从CCHP传递到散热器。 CCHP以氨为工作流体,LHP以丙烯为工作流体。精确的加热器控制器具有可调节的飞行设定点,用于控制LHP补偿室和探测器阵列xA1 ASIC温度。该散热器具有AZ-Tek的AZW-LA-II低日光吸收性白漆作为热涂层,位于散热器的防太阳侧。 BAT的热平衡(T / B)测试已成功完成。它验证了散热设计能够满足飞行散热环境中BAT的温度要求。通过LHP热系统成功完成了BAT检测器阵列的仪器级和天文台级热真空(TN)循环测试。本文介绍了T / B测试和T N循环测试的结果。

著录项

  • 作者

    Choi Michael K.;

  • 作者单位
  • 年度 2004
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信