The relative amount of distortion in the current generated by a PV system under low solar irradiance is known to be quite significant. This paper analyzes such distortion on the utility-side of the interconnection transformer thus including its excitation current. An approximate method that reveals the imbalance and distortion of both the phase and line currents in a 3-legged transformer is presented. The effect of these currents on those generated by the PV system is analyzed. The analysis is illustrated through an experimental test that was conducted on a 12 kW PV system which is connected to the grid through a 3-phase, 30 kVA, Δ-Y, 208/480 V transformer, when operating under low power production.
机译:已知在低太阳辐照度下由PV系统产生的电流中的相对变形的相对量是非常显着的。本文分析了互连变压器的效用侧的这种变形,因此包括其激励电流。呈现了一种概略的方法,揭示了3腿变压器中相位和线电流的不平衡和变形。分析了这些电流对PV系统产生的那些电流的影响。通过在12kW PV系统上进行的实验试验说明了分析,该试验通过3阶段,通过3阶段,30 kVA,Δ-y,208/480 V变压器在低功率产生时连接到电网。