A Tumor-mimic Model for Evaluating the Accuracy of HIFU Preclinical Studies: An In Vivo Study

机译:一种评价HIFU临床前研究准确性的肿瘤模拟模型:体内研究

获取原文

摘要

To date, the efficacy of ablative technologies such as HIFU for the treatment of liver tumors in humans has been studied in animal models without tumors or in small animals like rats and rabbits with established tumors. Because of the small size of these animals, the lesion produced by HIFU devices has to be small. Thus, the local and systemic effects of the treatment as encountered in humans cannot be studied. The purpose of this study was to use an in vivo tumor-mimic model to evaluate the accuracy of HIFU ablation in the liver in preclinical studies. Tumor mimics were created in in vivo porcine livers by injecting a 1-cc warm mixture of agarose, cellulose, glycerol and methylene blue, which formed 1-cm hyperechoic discrete lesions on sonograms. Three studies were carried out: (i) in vitro experiments were conducted to study the acoustical proprieties of the tumor mimics; (ii) in vivo experiments were conducted in 10 pigs to evaluate the tolerance of the tumor mimics when injected in the liver; (iii) ultrasound-guided HIFU ablation was performed in 10 pigs to demonstrate that it is possible to treat a predetermined zone accurately. It was shown that the acoustical properties of tumor mimics are visible in sonograms and do not modify the shape and dimensions of HIFU lesions. The local and biological tolerance of tumor mimics was excellent. In addition, it was demonstrated that the average difference between the predetermined location of the HIFU ablation and the actual coagulated area was 32%. Therefore, this tumor mimic can be used to teach HIFU ablation before starting clinical studies, especially if the ultrasound device is to be used manually, as the one presented in this study was.
机译:迄今为止,消融技术,如用于HIFU治疗人体肝脏肿瘤的疗效进行了研究在动物模型中没有肿瘤或小动物,如老鼠和兔子既定的肿瘤。因为这些动物的尺寸小,通过HIFU装置产生病变必须是小的。因此,作为人类遇到的治疗的局部和全身的效果无法进行研究。这项研究的目的是利用体内肿瘤模拟模型来评估在临床前研究肝脏HIFU消融的准确性。肿瘤模拟物在体内猪肝通过注入的琼脂糖的1毫升温热的混合物产生,纤维素,甘油和亚甲基蓝,其中形成在超声图1厘米高回声离散的损伤。三项研究中进行的:(ⅰ)在体外实验以研究肿瘤模拟物的声学礼节; (ⅱ)在体内实验在10头猪进行在肝脏中注射时,以评估肿瘤模拟物的耐受性; (ⅲ)超声引导HIFU消融在10头猪进行,以证明它可以精确地处理的预定区域。结果表明,肿瘤模仿的声学特性是在声谱图可见和不修改形状和HIFU病变的尺寸。肿瘤模仿的地方和生物耐受性良好。此外,证实了HIFU消融的预定的位置和实际的凝固区域之间的平均差异为32%。因此,这种肿瘤模拟物可用于教HIFU消融开始临床研究之前,特别是如果所述超声波装置是手动使用,如在本研究中提出的一个是。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号