Wind loads must be taken into account for the design of any outdoor structure. For solar trackers, the analysis of the wind loads presents a number of challenges as the existing, officially released tracker standards do not provide sufficient guidelines regarding how wind loads should be calculated and which assumptions should be applied. Building standards such as the Eurocode or US Building Code do not relate specifically to solar trackers and could result in overdesign. The IEC 62817 (Design Qualification For Solar Trackers) is in the final draft stage and addresses the issue of determining the winds loads on solar trackers. Three methods are described: wind tunnel analysis, CFD analysis, and an equation based calculation. This paper provides a comparison of the wind load results obtained using the IEC 62817 draft, wind tunnel tests and CFD analyses.
机译:任何室外结构的设计都必须考虑风荷载。对于太阳能跟踪器,风载荷的分析提出了许多挑战,因为现有的正式发布的跟踪器标准并未提供有关如何计算风载荷以及应采用哪些假设的足够指导原则。诸如《欧洲规范》或《美国建筑规范》之类的建筑标准并不专门与太阳能跟踪器相关,并且可能导致过度设计。 IEC 62817(太阳能跟踪器的设计资格)处于最终草案阶段,旨在解决确定太阳能跟踪器的风载荷的问题。描述了三种方法:风洞分析,CFD分析和基于方程的计算。本文对使用IEC 62817草案,风洞测试和CFD分析获得的风荷载结果进行了比较。