首页> 外文会议>Conference on Precision Electromagnetic Measurements >Error Analysis of an AC Voltage Differential Sampling System
【24h】

Error Analysis of an AC Voltage Differential Sampling System

机译:交流电压差分采样系统的误差分析

获取原文

摘要

This paper analyzes error sources of a differential sampling system. We derive the error transfer function and prove that the effect of gain error on the accuracy of the reconstructed sine wave measurement is significantly reduced by a switching method. The relationship between the differential coefficient and the differential signal have been analyzed. It is concluded that if the RMS amplitude error of sine wave being less than 0.05 μV/V, the system gain error should be less than 46 μV/V when the number of steps is 40 or greater.
机译:本文分析了差分采样系统的误差源。我们推出了错误传递函数并证明了通过切换方法显着降低了重建正弦波测量精度的增益误差的效果。已经分析了差分系数与差分信号之间的关系。得出结论,如果正弦波的幅度幅度小于0.05μV/ v,则当步骤数为40或更大时,系统增益误差应小于46μV/ v。