The voltage error associated with the leakage current of programmable Josephson voltage standards (PJVS) is one of the largest contributions to the uncertainty in direct comparison of voltage standards. Due to the parallel biasing scheme of the PJVS and the resulting multiple leakage paths, the quantities "leakage resistance" and "leakage current" are not necessarily equivalent. A method to measure and model the leakage current to ground for a given PJVS output voltage is presented. By upgrading simple components of the NIST system, the leakage current to ground can be reduced from 250 pA to 50 pAat 10 V.
机译:与可编程Josephson电压标准(PJV)的漏电流相关的电压误差是直接比较电压标准的不确定性的最大贡献之一。由于PJV的平行偏置方案和所得到的多个泄漏路径,数量“漏电阻”和“漏电流”不一定是等效的。提出了一种测量和模拟给定PJVS输出电压接地的漏电流的方法。通过升级NIST系统的简单组件,可以将漏电流从250 PA减少到50 PAAT 10 V.