首页> 外文会议>Conference on Precision Electromagnetic Measurements >Towards a BIPM On-Site Comparison Program for AC Voltages Based on the Differential Sampling Technique
【24h】

Towards a BIPM On-Site Comparison Program for AC Voltages Based on the Differential Sampling Technique

机译:朝向基于差分采样技术的交流电压的BIPM现场比较计划

获取原文

摘要

BIPM has conducted a few pilot studies to investigate the possibility of extending the protocol of the BIPM program of on-site DC Josephson Voltage Standard comparisons (BIPM.EM-KI0.b) to AC voltages. On-site indirect comparisons have been performed for AC low frequency sinewaves, at 1 V and 6.5 V rrns, using the new BIPM Programmable Josephson Voltage Standard and the differential sampling method. A relative agreement within a few parts in 10~7 can typically be achieved using a commercial calibrator as a transfer standard. The noise of the phase locking process appears to be the limiting factor. We have been investigating other AC generators as possible candidates for an accurate transfer standard.
机译:BIPM已经进行了一些试点研究,以调查将现场DC Josephse将标准比较(BIPM.EM-Ki0.B)的BIPM程序的协议扩展到交流电压。使用新的BIPM可编程Josephson电压标准和差分采样方法,已经为AC低频型电源,1 V和6.5 V RRNS执行了现场间接比较。通常可以使用商业校准器作为转移标准来实现10〜7内的几个部分内的相对协议。锁相过程的噪声似乎是限制因素。我们一直在调查其他交流发电机,尽可能为准确的转移标准进行候选人。