首页> 外文会议>Conference on Precision Electromagnetic Measurements >Spectral Leakage Errors When Using an Agilent 3458A to Measure Phase at Mains Power Frequencies
【24h】

Spectral Leakage Errors When Using an Agilent 3458A to Measure Phase at Mains Power Frequencies

机译:使用Agilent 3458A时使用Agilent 3458A测量电源功率频率的阶段的光谱泄漏误差

获取原文

摘要

By employing standard FFT methods, the phase of a single tone of a mains energy waveform can be derived from measurements made using an Agilent 3458A. Phase errors arising from the finite sampling interval resolution can be corrected when the signal frequency is known. Knowing the form of the resulting spectral leakage errors can assist in correcting the measured phase to within 0.002 deg. In the SSDC mode of the 3458A, these phase errors reveal an unexpected step change in the 3458A's effective sampling interval resolution as the sampling rate is changed.
机译:通过采用标准FFT方法,可以从使用Agilent 3458a制造的测量来源于电源波形的单个音调的相位。当信号频率已知时,可以校正由有限采样间隔分辨率产生的相位误差。了解所产生的光谱泄漏误差的形式可以有助于将测量的相校正到0.002°内。在3458A的SSDC模式下,这些相位误差会显示3458A有效的采样间隔分辨率中的意外步骤变化,因为采样率改变。