首页> 外文会议>International Workshop on Thermal investigations of ICs and Systems >In situ thermal reliability testing methodology for novel thermal interface materials
【24h】

In situ thermal reliability testing methodology for novel thermal interface materials

机译:新型热界面材料的原位热可靠性测试方法

获取原文

摘要

A novel in situ reliability testing method and the prototype of an industrially applicable automated system (the Viking Reliability Tester) was described in this paper for the characterization of TIM aging effects in semiconductor devices. The introduced reliability testing hardware-software framework utilizes Mentor Graphics T3Ster thermal transient tester to analyze the stress-induced deviations in the heat flow path from the pre-stress reference results. Measurement results collected during the active or passive cycling of the DUTs at regular intervals serve as basis for the comparison. The details of the degradation process can be used as input for life-time prediction and for physics of failure modeling. The practical application of the concept was demonstrated on power LEDs, including details about pre-stress measurement results and aging test-plan.
机译:为了描述半导体器件中TIM老化效应的特性,本文描述了一种新颖的现场可靠性测试方法和一种工业上适用的自动化系统(Viking可靠性测试仪)的原型。引入的可靠性测试硬件-软件框架利用Mentor Graphics T3Ster热瞬态测试仪来分析应力在热流路径中与预应力参考结果产生的偏差。在DUT的定期或主动循环期间收集的测量结果将用作比较的基础。退化过程的详细信息可以用作生命周期预测和故障建模物理的输入。该概念的实际应用已在功率LED上进行了演示,包括有关预应力测量结果和老化测试计划的详细信息。