首页> 外文会议>Conference on earth observing systems >Relative Spectral Response Corrected Calibration Inter-comparison of S-NPP VIIRS and Aqua MODIS Thermal Emissive Bands
【24h】

Relative Spectral Response Corrected Calibration Inter-comparison of S-NPP VIIRS and Aqua MODIS Thermal Emissive Bands

机译:S-NPP VIIRS和Aqua MODIS热发射带的相对光谱响应校正校准比对

获取原文

摘要

The S-NPP Visible Infrared Imaging Radiometer Suite (VIIRS) instrument is built with strong heritage from EOS MODIS, and has very similar thermal emissive bands (TEB) calibration algorithm and on-board calibrating source - a Ⅴ-grooved blackbody. The calibration of the two instruments can be assessed by comparing the brightness temperatures retrieved from VIIRS and Aqua MODIS simultaneous nadir observations (SNO) from their spectrally matched TEB. However, even though the VIIRS and MODIS bands are similar there are still relative spectral response (RSR) differences and thus some differences in the retrieved brightness temperatures are expected. The differences depend on both the type and the temperature of the observed scene, and contribute to the bias and the scatter of the comparison. In this paper we use S-NPP Cross-track Infrared Sounder (CrIS) data taken simultaneously with the VIIRS data to derive a correction for the slightly different spectral coverage of VIIRS and MODIS TEB bands. An attempt to correct for RSR differences is also made using MODTRAN models, computed with physical parameters appropriate for each scene, and compared to the value derived from actual CrIS spectra. After applying the CrIS-based correction for RSR differences we see an excellent agreement between the VIIRS and Aqua MODIS measurements in the studied band pairs M13-B23, M15-B31, and M16-B32. The agreement is better than the VIIRS uncertainty at cold scenes, and improves with increasing scene temperature up to about 290 K.
机译:S-NPP可见光红外成像辐射计套件(VIIRS)仪器具有EOS MODIS的悠久传统,并具有非常相似的热发射谱带(TEB)校准算法和车载校准源-带有V槽的黑体。可以通过比较从光谱匹配的TEB从VIIRS和Aqua MODIS同时最低点观测值(SNO)中检索到的亮度温度来评估这两种仪器的校准。但是,即使VIIRS和MODIS频段相似,仍然存在相对光谱响应(RSR)差异,因此,预计恢复的亮度温度会有一些差异。差异取决于所观察场景的类型和温度,并导致比较的偏差和散布。在本文中,我们使用与VIIRS数据同时获取的S-NPP跨轨红外测深仪(CrIS)数据来得出对VIIRS和MODIS TEB频段的频谱覆盖率略有不同的校正。还尝试使用MODTRAN模型校正RSR差异,并使用适合每个场景的物理参数进行计算,并将其与从实际CrIS光谱得出的值进行比较。在对RSR差异应用基于CrIS的校正后,我们发现在研究的频带对M13-B23,M15-B31和M16-B32中,VIIRS和Aqua MODIS测量值之间具有极好的一致性。该协议优于冷场中VIIRS的不确定性,并且随着场景温度升高至大约290 K而提高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号