High-voltage disconnectors are the largest and most important primary device in the transformer substation. There are many problems during the closing of the disconnector, such as not in place, over the place, the contactor is loose and so on. This paper presents the Finite Element Analysis (FEA) of disconnector GW4D-126D(W) under different closing states performed by ANSYS Workbench. The experimental modal analysis using vibrometer was conducted to verify the accuracy of the simulation. Through the analysis of the vibration signal in different closing states, the characteristic parameter can be extracted, and then the closing state can be distinguished by the characteristic parameter like frequency.
机译:高压隔离开关是变电站中最大,最重要的主要装置。在断开的截止部件期间存在许多问题,例如不在适当位置,在该地方,接触器松动等等。本文在由ANSYS工作台执行的不同闭合状态下介绍了断开的磁盘连接器GW4D-126D(W)的有限元分析(FEA)。使用振动计进行实验模态分析以验证模拟的准确性。通过分析不同闭合状态的振动信号,可以提取特征参数,然后可以通过频率的特征参数来区分闭合状态。