A prototype of high gradient magnetic filter is designed and fabricated, and the electrical coils, which generate a 1 Tesla background magnetic field, are cooled by evaporative cooling system. The operating magnetic flux density distribution is computed carefully by magnetic circuit method and finite element method, and the operating temperature distribution of electrical coils is computed too by finite element method. The test values of the distribution of magnetic flux density and temperature are in accord with design computations.
展开▼