首页> 外文会议>IEEE International Symposium on Biomedical Imaging >A spinning tangent based CAD system for detection of flat lesions in CT colonography
【24h】

A spinning tangent based CAD system for detection of flat lesions in CT colonography

机译:基于旋转切线的CAD系统,用于检测CT上骨析中的扁平病变

获取原文

摘要

While many computer-aided detection (CADe) systems for CT colonography can detect polypoid lesions at a high sensitivity level, very few are targeted toward detecting flat lesions. Research has shown that flat lesions are more likely to contain carcinoma than polypoid lesions; therefore, it is imperative that they be adequately detected in screenings and examinations. However, current CADe systems systems have a low sensitivity for flat lesions, with a relatively high false-positive (FP) rate. By generating a surface mesh of the colon and spinning a tangent line at each point of the mesh, we have developed a new CADe system for detecting flat lesions. With our system, we detected 82% (23/28) of flat lesions in our dataset with a small number of FPs (4.5 per patient), whereas a modified shape-index-based CADe system detected 68% (19/28) of them with 10 FPs per patient.
机译:虽然用于CT上影的许多计算机辅助检测(CADE)系统可以以高灵敏度水平检测息肉膜病变,但很少靶向检测扁平病变。 研究表明,扁平病变更可能含有癌瘤癌; 因此,在筛选和考试中必须充分检测到它们。 然而,目前的CADE系统系统对扁平病变具有低灵敏度,具有相对高的假阳性(FP)速率。 通过产生结肠的表面网并在网格的每个点旋转切线线,我们开发了一种用于检测平坦病变的新CADE系统。 通过我们的系统,我们在我们的数据集中检测到82%(23/28)的数据集中的平坦病变(每位患者4.5),而基于修改的形状指数的CADE系统检测到68%(19/28) 他们每位患者10 FPS。