首页> 外文会议>IEEE International Symposium on Biomedical Imaging >Simultaneous Estimation of input functions: The B-SIME method
【24h】

Simultaneous Estimation of input functions: The B-SIME method

机译:同时估计输入功能:B-SIME方法

获取原文

摘要

Using Positron Emission Tomography for dynamic tracer mapping requires the knowledge of the arterial plasmatic activity concentration (PTAC). The reference method to obtain it is arterial sampling, not applicable in clinical studies because invasive and dangerous. The Simultaneous Estimation (SIME) method aims to estimate simultaneously the PTAC and the organ pharmacokinetic parameters from the time-activity curve of some tissues (three or four), with or without the help of some blood samples. The improvement proposed here, the B-SIME method, uses the results of the SIME on hundreds of sets of three tissues to evaluate the PTAC. Here an application for the 18F - FDG in human brain is shown; good results for the estimation of the PTAC were obtained, specially when using one late venous blood sample, for simulated and real data.
机译:使用正电子发射断层扫描用于动态示踪器映射需要了解动脉等离子体活性浓度(PTAC)。 获得它的参考方法是动脉采样,不适用于临床研究,因为侵入性和危险性。 同时估计(SIME)方法旨在同时估计PTAC和器官药代动力学参数,其中一些组织(三四或四),有或没有一些血样的帮助。 这里提出的改进,B-SIME方法,使用SIME的结果对数百组三组组织来评估PTAC。 这里显示了人脑中 18 f - fdg的应用; 获得PTAC估计的良好结果,特别是使用一个晚期静脉血液样本,用于模拟和实际数据。

著录项