MR measurements from an EPI sequence produce Nyquist ghost artifacts that originate from inconsistencies between odd and even echoes. By converting the ghost correction problem to an interpolation problem from uniformly downsampled even and odd phases, here we propose a single pass reference free ghost artifact removal algorithm. Specifically, our algorithm exploits an observation that the difference between the even and odd echoes is a Fourier transform of an underlying sparse image. Accordingly, we can construct a rank-deficient Hankel structured matrix in k-space, whose missing data can be recovered using recently proposed annihilating filter-based low rank Hankel structured matrix completion approach (ALOHA). The proposed method was applied to EPI data for both single and multi-coil acquisitions. Experimental results using in-vivo data confirmed that the proposed method can completely remove ghost artifacts successfully without any pre-scan data.
机译:来自EPI序列的MR测量会产生奈奎斯特幽灵伪像,它起源于奇数甚至回声之间的不一致。通过将幽灵校正问题转换为从均匀下采样的偶数和奇数阶段转换到插值问题,这里我们提出了一个通过参考的游离鬼魂伪像去除算法。具体地,我们的算法利用了观察到偶数和奇波之间的差异是底层稀疏图像的傅里叶变换。因此,我们可以在K空间中构建秩缺陷的Hankel结构化矩阵,其缺失数据可以使用最近提出的基于灭菌滤波器的低等级Hankel结构矩阵完成方法(Aloha)。所提出的方法被应用于单一和多线圈采集的EPI数据。使用体内数据的实验结果证实,所提出的方法可以在没有任何预扫描数据的情况下成功删除Ghost文物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号