This paper is mainly aimed at the structural performance of compound cold-formed galvanized steel beams under fire conditions, based on the results of a large programme of experimental tests and numerical simulations, using the advanced finite element program ABAQUS.The main objective of this research was to assess the failure modes, the critical temperature and the critical time of the studied beams.Other important goals of this research work were also to investigate the influence of the cross-sections (C, lipped-I, R and 2R beams) and, above all, of the axial restraint (0, 0.45, 1, 7.5, 15, 30, ∞ kN/mm) to the thermal elongation of the beam and the rotational restraint at beam supports (0, 15, 150,300, 1200 and ∞ kN.m/rad) on the fire resistance of this kind of beams.
机译:本文基于先进的有限元程序ABAQUS,通过大量实验测试和数值模拟的结果,主要针对复合冷弯镀锌钢梁在火条件下的结构性能。该研究工作的其他重要目标还包括研究横截面(C,I型,R型和2R型梁)的影响,以及尤其是对梁的热伸长的轴向约束(0,0.45,1,7.5,15,30,∞kN / mm)和梁支撑处的旋转约束(0,15,150,300,1200和∞ kN.m / rad)。