A numerical parametric investigation into the response of axially and rotationally restrained compound cold-formed steel beams in fire has been carried out. A suitable finite element model was validated against experimental fire tests. Some parameters that could have influence on the behaviour of these beams were evaluated, such as the section geometry, initial applied load, slenderness and influence of the axial and rotational restraints. The results showed that the critical temperature of axially restrained beams may drop significantly (reaching a 50% reduction) and, beyond a certain value of axial or rotational restraint it may be no longer possible to change its fire resistance. Furthermore, it was still concluded that the methods established in EN1993-1.2:2004 are not appropriate for the fire design of these beams (reaching relative differences in the order of 20% and some predictions can be unsafe). (C) 2016 Elsevier Ltd. All rights reserved.
机译:进行了轴向和旋转约束的复合冷弯型钢梁在火灾中的响应的数值参数研究。针对实验耐火试验验证了合适的有限元模型。评估了可能影响这些梁性能的一些参数,例如截面几何形状,初始施加载荷,细长度以及轴向和旋转约束的影响。结果表明,轴向约束梁的临界温度可能会显着下降(降低50%),并且超过一定的轴向约束或旋转约束值后,可能不再可能改变其耐火性。此外,仍然得出结论,EN1993-1.2:2004中建立的方法不适用于这些梁的火灾设计(相对差异达到20%左右,有些预测可能是不安全的)。 (C)2016 Elsevier Ltd.保留所有权利。