In order to keep a low false alarm rate of 1/year-kilometre, and in order to launch the fire alarm correctly in the initial stage of such a fire as occurred in a car, a method of threshold selection for a fire alarm system particularly applied in traffic tunnels is discussed in this thesis. Each fire alarm detector randomly collects environmental temperature rise gradients (TRG) and the probability that thus-collected TRG is higher than the lower limit of fire alarm threshold shall be lower than 3 x10-10, the upper limit of fire alarm threshold is defined as the minimum TRG corresponding to a fire with a heat release rate of no less than 1.2MW in the related tunnel. The author has given a detailed description of tunnel fire validation testing and methods for data collection, analysis and statistics in an operating tunnel. The method for rational selection of fire alarm threshold has a universal significance to the further improvement of reliability and practicality of a fire alarm system in traffic tunnels.
机译:为了保持1 /公里的低误报率,并且为了在汽车发生火灾的初期正确地发出火灾警报,特别是一种用于火灾警报系统的阈值选择方法。本文讨论了在交通隧道中的应用。每个火灾报警探测器随机收集环境温度上升梯度(TRG),并且由此收集到的TRG高于火灾报警阈值下限的概率应小于3 x10-10,火灾报警阈值上限定义为在相关隧道内,与释放热量不低于1.2MW的火对应的最小TRG。作者详细介绍了隧道火灾验证测试以及在用隧道中数据收集,分析和统计的方法。合理选择火灾报警阈值的方法对于进一步提高交通隧道火灾报警系统的可靠性和实用性具有普遍意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号