首页> 外文会议>IET International Conference on Power Electronics, Machines and Drives >Achieving the desired transformer leakage inductance necessary in DC-DC converters for energy storage applications
【24h】

Achieving the desired transformer leakage inductance necessary in DC-DC converters for energy storage applications

机译:在DC-DC转换器中实现所需的变压器泄漏电感,用于储能应用

获取原文

摘要

This paper presents a cost effective winding design and evaluation of a medium frequency isolation transformer typically used in bidirectional isolated DC/DC converters. Since leakage inductance and winding resistance of a high frequency transformer are interdependent, any attempt to increase the leakage inductance by adjusting the winding arrangement increases the resistance as well and impacts the efficiency. This paper proposes the use of flux diverter caps made of a relatively small amount of ferrite material to get the desired value of inductance whilst maintaining the losses in the windings at reasonable levels. The proposal is experimentally evaluated on a 5kW prototype.
机译:本文介绍了通常用于双向隔离的DC / DC转换器的中频隔离变压器的成本效益绕组设计和评估。由于高频变压器的漏电电感和绕组阻力是相互依赖的,因此通过调节绕组布置来增加漏电电感的任何尝试也增加了电阻并影响效率。本文提出了使用相对少量的铁氧体材料制成的助焊剂转向帽,以获得所需的电感值,同时在合理的水平下保持绕组中的损失。该提案在实验上评估了5kW原型。