A new way which can reduce environment noise underground in mine tunnel is produced. By analysis of the noise in central water pump house, point out that noise underground is mainly consist of base frequency and harmonic frequency coming from electric motor and transformer, with its frequency coverage below 650Hz . Acoustic spread environment in mine tunnel is similar to that in duct. Therefore, it is suitable to reduce noise by active noise control method. According to installation situation of equipment and noise distribution characters, feed forward FXLMS algorithm is used. Simulated results based on Matlab proved that there is an average of 13dB reduction using active noise control system.
机译:一种可以减少矿井隧道环境噪声的新方法。 通过分析中央水泵屋中的噪声,指出,地下噪声主要由来自电动机和变压器的基础频率和谐波频率组成,其频率覆盖率低于650Hz。 矿井隧道中的声学传播环境与管道中的隧道相似。 因此,适用于通过主动噪声控制方法降低噪声。 根据设备和噪声分布字符的安装情况,使用前馈FXLMS算法。 基于MATLAB的模拟结果证明了使用主动噪声控制系统的平均减少了13dB。