A new way which can reduce environment noise underground in mine tunnel is produced. By analysis of the noise in central water pump house, point out that noise underground is mainly consist of base frequency and harmonic frequency coming from electric motor and transformer, with its frequency coverage below 650Hz . Acoustic spread environment in mine tunnel is similar to that in duct. Therefore, it is suitable to reduce noise by active noise control method. According to installation situation of equipment and noise distribution characters, feed forward FXLMS algorithm is used. Simulated results based on Matlab proved that there is an average of 13dB reduction using active noise control system.
机译:提出了一种减少矿井井下环境噪声的新方法。通过对中央水泵房噪声的分析,指出地下噪声主要由电动机和变压器产生的基频和谐波频率组成,其频率覆盖范围在650Hz以下。矿山隧道的声波传播环境与管道中的声波传播环境相似。因此,通过主动噪声控制方法来降低噪声是合适的。根据设备安装情况和噪声分布特点,采用前馈FXLMS算法。基于Matlab的仿真结果证明,使用有源噪声控制系统可以平均降低13dB。